1.
Modern Clinical Nursing ; (6): 44-46, 2015.
Article in Chinese | WPRIM | ID: wpr-460744

ABSTRACT

Objective To explore the effects of two lubricants on skin preparation from donor site in patients with skin flap transplantation. Methods According to digit number table, 83 patients undergoing wound repair using modified fascia flap were divided into observation group (n=41) and control group (n=42). The former group were treated with Johnson K-Y Lubricant, while the latter with talcum powder. The two groups were compared in terms of the skin flap quality from donor site, pain degree and number of bacteria before and after transplantation. Results There was no significant difference in bacteria number before and after transplantation in the two groups (P>0.05), but the difference between the groups was significant (P<0.01). The flap preparation quality in the observation group was significantly better than that of control group and the pain degree was significantly lower than that of observation group. Conclusion Johnson K-Y Lubricant can significantly improve flap preparation quality and reduce pain.

2.
Chinese Journal of Practical Nursing ; (36): 64-66, 2011.
Article in Chinese | WPRIM | ID: wpr-414537

ABSTRACT

Objective To carry out bacteriological analysis between re-used and disposable oxygen humidification devices. Methods Reused oxygen equipment and disposable oxygen moisture bottles from 6 randomly selected elderly wards were collected, patients who used oxygen will be randomized into 3 groups, group A used cold water as the oxygen humidification liquid, group B used distilled water as humidification liquid, group C used AQUAPAK disposable oxygen humidification devices, sample taking in group A and group B happened on every Monday and Thursday before the replacement of sample moisture bottles, sample was taken in group C after the use of disposable oxygen humidification devices, according to "hospital disinfection health standards" (GB5982-1995)sampling method of disinfection liquid sample was taken and sent to test in the disinfectant laboratory. Results Of 61 samples in group A bacteria cartier rate was 81.97%, bacteria carrier rate of 71 samples in group B was 47.89%, of 52 samples in group C the carrier rate was 0. The comparing of bacterial contamination rate of three kinds of oxygen moisture bottles after using was statistically significant. Take group A, B for comparison, the average severity level of bacteria in group A is higher than group B. In group A, the level of the Gram-negative bacteria as well as Gram-positive bacteria colonization was higher than group B. Conclusions Whether use of cold water or distilled water, oxygen humidification liquids have different degrees of pollution. Currently there is no general criteria and norms in the context of sterilization of oxygen humidification, for patients on long-term oxygen using, to choose disposable oxygen humidification device to reduce the incidence of hospital infections is recommended.

3.
Clinical Medicine of China ; (12): 248-250, 2010.
Article in Chinese | WPRIM | ID: wpr-390530

ABSTRACT

Objective To explore clinical value of tumor specific growth factors (TSGF) in serum and bronchoalveolar lavage fluid (BALF) on differential diagnosis of benign and malignant periphery solitary pulmonary nodules (PSPN). Methods Serum and BALF from both normal and afflicted side were collected from 211 patients with PSPN(case group) and from 196 patients without any type of tumor (control group). TSGF and carcinoembry-onic antigen (CEA) in serum and BALF were measured in both groups. Results In the malignant PSPN patients, CEA in serum, normal and afflicted side were 28.73 (SD: 15.61) μg/L,63.31 (SD:21.28) μg/L and 85.54(SD: 26.19)μg/L,respectively, which was significantly higher than that of the benign PSPN patients (7.21(SD:2.43) μg/L, 12.36(SD:6.93)μg/L and 14.65 (SD:8.07)μg/L,respectively), as well as that of the control group (4.68 (SD: 1.25) μ/L and 11.06(SD:8.03) μg/L in serum and BALF, respectively (P < 0.05). TSGF in the serum and BALF from the normal and afflicted side of malignant PSPN patients was 88.73 (SD:13.51)μg/L, 110.73 (SD: 18.64) μg/L and 162.80(SD:58.89) μg/L, respectively, which were significantly higher than that of the benign PSPN patients (56.31(SD: 2.43) μg/L, 79.25 [SD: 36.86] and 86.29 (SD: 37.07) μg/L, respectively) (P <0.05). Furthermore, in the malignant PSPN patients, TSGF and CEA in the afflicted side were significantly higher than that of the normal side. Sensitivity, specificity and accuracy of TSGF in BALF from the afflicted side for malig-nant diagnosis were 86.6%,100.0% and 98.6%,respectively,which was higher than that of CEA (70.2% ,78. 9% and 76.5% respectively) and that of serum TSGF (73.1% ,88.9% and 85.7% respectively). Conclusions TSGF in bronchoalveolar lavage fluid and serum has a significant role in differential diagnosis of benign and malig-nant periphery solitary pulmonary nodules. Furthermore, measurement of TSGF in bilateral BALF is helpful in diag-nosis of tumor location.

4.
Chinese Journal of Medical Imaging Technology ; (12): 1296-1299, 2009.
Article in Chinese | WPRIM | ID: wpr-472387

ABSTRACT

Objective To explore the application of the tracking scan technique in 16-slice spiral CT angiography, in order to improve the quality of CTA. Methods Three hundred patients who were divided into three groups randomly underwent CTA in tracking, testing and estimation scan respectively with GE LightSpeed 16-slice spiral CT. The data of all patients were transmitted to the workstation (AW4.2) and reconstructed. The quality of all images were evaluated by three experienced doctors with double-blind method and divided into four grades (A, B, C and D) from optimal to poor. Results The rate of grade A, B, C and D was 89.00%, 7.00%, 4.00% and 0 respectively for tracking scan, 70.00%, 11.00%, 15.00% and 4.00% respectively for testing scan, while 61.00%, 13.00%, 21.00% and 5.00% respectively for estimation scan. Conclusion Tracking scan technique is superior to testing and estimation scan in image quality of 16-slice spiral CT angiography.

5.
International Journal of Biomedical Engineering ; (6)2006.
Article in Chinese | WPRIM | ID: wpr-560240

ABSTRACT

Biodegradable polymers as drug delivery systems have attracted investigators. They degrade in biological fluids to produce biocompatible and nontoxic products, which could be removed from the body by normal physiological pathways without extra surgical removal. In this article, literatures on biodegradable polymers mainly served as matrix in controlled release systems are analyzed and reviewed.

6.
Chinese Journal of Practical Nursing ; (36)2006.
Article in Chinese | WPRIM | ID: wpr-528263

ABSTRACT

Objective To study the different effects when using the air bubble filtering apparatus and the general filtering apparatus.Methods Divided 50 cases into the control group(23 cases) and the experimental group(27 cases).The air bubble filtering apparatus was used in the experimental group,while the general filtering apparatus was used in the control.Compare the filtering effects between the two groups.Results The filtering effects in the experimental group was better than that of in the control group,P

7.
Chinese Journal of Nosocomiology ; (24)2005.
Article in Chinese | WPRIM | ID: wpr-594937

ABSTRACT

OBJECTIVE To evaluate the cleaning efficacy of the automatic cleaning machine and the risk factors to ensure the effect of disinfection and sterilization. METHODS Cleaning efficacy of the automatic cleaning machines was detected by STF cleaning test card.It was put in the first cabin of every automatic cleaning machine.And it was also tested for these factors in determining cleaning qualities such as enzyme concentration,water temperature and pieces of instruments washed. RESULTS The cleaning efficacy of the automatic cleaning machines was 98.9% in the continuous two years.The qualified rate was 98.6% for surgical instruments,99.4% for all instrument in clinical sections. CONCLUSIONS The machine is suitable for the cleaning of surgical instruments.It also raises working efficiency,cutting down the cost of repairs and maintenance,reducing the chances of injury and infections in nurses who performed manual cleaning precedures.The procedures of the STF cleaning test card in detecting the cleaning efficacy is simpler,safer,and suitable for clinical applications.

8.
Chinese Journal of Nosocomiology ; (24)1994.
Article in Chinese | WPRIM | ID: wpr-593965

ABSTRACT

OBJECTIVE To investigate the trend of distribution and drug resistance of clinical isolates of Enterobacter cloacae during the last three years in our hospital. METHODS Strains collected from daily specimens were identified and drug resistantce with SENSITITRE bacteria analysis system. RESULTS The most strains were isolated from samples of sputum,urine,nad other excretion. The drug resistance rates to imipenem and cefepime were less than 32%. Cefoxitin,ampicillin and cefazolin were ineffective to contralE. cloacae. The drug resistance rates to penicillins,cephalosporins,chloramphenicol and aminoglycoside antibiotics increased more than 20% in last three years. CONCLUSIONS E. cloacae is multiple-resistant to antibiotics and displays higher levels of antibiotic resistance. It is suggested that antibiotics be used reasonably under the guidance of antibiotic susceptibility testing.